BARENS Inc. Wholesale Pressure Washers, Parts and Accessories BARENS PHONE: (800) 676-0607
HOME CATALOG CONTACTS LINKS NEWS SEARCH   HELP

Item DescriptionStatusStock No.
SCALTROL SC-100 WATER TREATMENT SYSTEMIn Stock5041

Product Information
GENERAL INFORMATION

Most water supplies are usually saturated with large amounts of minerals, such as calcium carbonate (lime scale), copper, iron, copper, iron, and manganese, which can cause corrosion and scaling. When water is saturated with minerals, any increase in temperature or pressure drop will cause the minerals to form scale. So, water passing through a water faucet, water heater, or water line, will change the waters ability to hold the dissolved minerals in suspension.

Scaltrol stops mineral scale by introducing a measured amount of polyphosphate into the water. The mineral molecules, which have a positive charge, are attracted to the negative charge of the polyphosphate. The mineral molecules are unable to join together, so scale is unable to form. Scaltrol has developed a patented venturi dispensing head which provides an effective and efficient feed rate of the polyphosphates.

A scaltrol unit is easy to install because it is non-electrical, non-magnetic, and non-mechanical.

Product Photo

Technical Notes
The Scaltrol unit may be fitted on hot or cold waterlines. Water pressure for effective dispensing of Scaltrol should NOT exceed 55 PSI and check valve must be installed before the Scaltrol unit. The top of the unit must be fitted in a horizontal position.

SPECIFICATIONS:

  • Waterflow: up to 10 GPM
  • Maximum Pressure Head & Sump: 125 PSI
  • Maximum Temperature Head & Sump: 150 Degrees F.
  • Line Size: 1/2" & 3/4"
  • Dimensions: SC-50: 4.5" wide and 7.5" tall SC-100: 4.5" wide and 12.5" tall


| HOME | CATALOG | CONTACTS | LINKS | NEWS | SEARCH | HELP |